Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 225
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599692

RESUMEN

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
2.
J Clin Med ; 13(5)2024 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-38592382

RESUMEN

Background: Currently, transcatheter aortic valve implantation (TAVI) is the standard procedure recommended for patients over 75 years of age with symptomatic aortic valve stenosis. Percutaneous transfemoral (TF) access is the main route used to perform the procedure. Among periprocedural complications, access-related ones are the most frequent, potentially leading to prolonged in-hospital stays and transfusions. Methods: We performed a retrospective analysis of prospectively collected data on consecutive patients undergoing TF-TAVI with the latest generation balloon-expandable transcatheter valve between 2013 and 2022. Results: A total of 600 patients were analyzed, differentiating the population between ultrasound-guided and blind common femoral artery puncture. Valve Academic Research Consortium 3 (VARC-3)criteria were used to report at 30 days and follow-up. In our propensity-matched comparison of the two groups, we found a strong reduction in access-related complications in the echo-guided group, particularly in terms of reduction of major and minor bleedings. We also found a significant trend in reduction of local complications, such as pseudoaneurysms, hematomas, arterio-venous fistulas, dissection of the femoral or iliac arteries, and stenosis. Conclusions: Although there is a lack of consensus on the role of ultrasound-guided puncture, we found better outcomes for patients having an echo-guided puncture of the main access, particularly with regard to access-related complications, early mobilization, and early discharge home.

3.
Eur Heart J ; 2024 Mar 30.
Artículo en Inglés | MEDLINE | ID: mdl-38554125

RESUMEN

BACKGROUND AND AIMS: There is significant potential to streamline the clinical pathway for patients undergoing transcatheter aortic valve implantation (TAVI). The purpose of this study was to evaluate the effect of implementing BENCHMARK best practices on the efficiency and safety of TAVI in 28 sites in 7 European countries. METHODS: This was a study of patients with severe symptomatic aortic stenosis (AS) undergoing TAVI with balloon-expandable valves before and after implementation of BENCHMARK best practices. Principal objectives were to reduce hospital length of stay (LoS) and duration of intensive care stay. Secondary objective was to document patient safety. RESULTS: Between January 2020 and March 2023, 897 patients were documented prior to and 1491 patients after the implementation of BENCHMARK practices. Patient characteristics were consistent with a known older TAVI population and only minor differences. Mean LoS was reduced from 7.7 ± 7.0 to 5.8 ± 5.6 days (median 6 vs. 4 days; P < .001). Duration of intensive care was reduced from 1.8 to 1.3 days (median 1.1 vs. 0.9 days; P < .001). Adoption of peri-procedure best practices led to increased use of local anaesthesia (96.1% vs. 84.3%; P < .001) and decreased procedure (median 47 vs. 60 min; P < .001) and intervention times (85 vs. 95 min; P < .001). Thirty-day patient safety did not appear to be compromised with no differences in all-cause mortality (0.6% in both groups combined), stroke/transient ischaemic attack (1.4%), life-threatening bleeding (1.3%), stage 2/3 acute kidney injury (0.7%), and valve-related readmission (1.2%). CONCLUSIONS: Broad implementation of BENCHMARK practices contributes to improving efficiency of TAVI pathway reducing LoS and costs without compromising patient safety.

4.
JACC Cardiovasc Interv ; 17(5): 681-692, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38479968

RESUMEN

BACKGROUND: The performance of latest iteration transcatheter aortic valve replacement platforms in patients with small aortic anatomy remains underexplored. OBJECTIVES: The aim of this study was to evaluate effectiveness and performance between the self-expanding (SE) Evolut PRO and PRO+ and the balloon-expandable (BE) SAPIEN ULTRA in patients with small aortic annuli. METHODS: Data from the OPERA-TAVI (Comparative Analysis of Evolut PRO vs. SAPIEN 3 ULTRA Valves for Transfemoral Transcatheter Aortic Valve Implantation) registry were used, with 1:1 propensity score matching. Primary endpoints included 1-year effectiveness composite (all-cause mortality, disabling stroke, or heart failure hospitalization) and 30-day device-related (hemodynamic structural valve dysfunction and nonstructural valve dysfunction) outcomes. RESULTS: Among 3,516 patients, 251 matched pairs with aortic annular area <430 mm2 were assessed. The 1-year primary effectiveness outcome did not differ significantly between cohorts (SE 10.8% vs BE 11.2%; P = 0.91). The 30-day device-oriented composite outcome was more favorable in the Evolut PRO group (SE 4.8% vs BE 10.4%; P = 0.027). Notably, SE valve recipients showed higher rates of disabling stroke (SE 4.0% vs BE 0.0%; P < 0.01) and paravalvular leaks (mild or greater: SE 48.5% vs BE 18.6% [P < 0.001]; moderate: SE 4.5% vs BE 1.2% [P = 0.070]). The BE group had higher rates of prosthesis-patient mismatch (moderate or greater: SE 16.0% vs BE 47.1% [P < 0.001]; severe: SE 1.3% vs BE 5.7% [P = 0.197]) and more patients with residual mean gradients >20 mm Hg (SE 1.0% vs BE 13.5%; P < 0.001). CONCLUSIONS: In patients with small aortic annuli, transcatheter aortic valve replacement with latest iteration devices is safe. SE platforms are associated with more favorable device performance in terms of hemodynamic structural and nonstructural dysfunction. Randomized data are needed to validate these findings and guide informed device selection.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología
5.
Am J Cardiol ; 219: 60-70, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38401656

RESUMEN

Evidence regarding gender-related differences in response to transcatheter aortic valve implantation according to the valve type is lacking. This study aimed to evaluate the impact of gender on the treatment effect of Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices on clinical outcomes. The Comparative Analysis of Evolut PRO vs SAPIEN 3 Ultra Valves for Transfemoral Transcatheter Aortic Valve Implantation (OPERA-TAVI) is a multicenter, multinational registry including patients who underwent the latest-iteration PRO or ULTRA implantation. Overall, 1,174 of 1,897 patients were matched based on valve type and compared according to gender, whereas 470 men and 630 women were matched and compared according to valve type. The 30-day and 1-year outcomes were evaluated. In the PRO and ULTRA groups, men had a higher co-morbidity burden, whereas women had smaller aortic root. The 30-day (device success [DS], early safety outcome, permanent pacemaker implantation, patient-prosthesis mismatch, paravalvular regurgitation, bleedings, vascular complications, and all-cause death) and 1-year outcomes (all-cause death, stroke, and heart failure hospitalization) did not differ according to gender in both valve groups. However, the male gender decreased the likelihood of 30-day DS with ULTRA versus PRO (p for interaction = 0.047). A higher risk of 30-day permanent pacemaker implantation and 1-year stroke and a lower risk of patient-prosthesis mismatch was observed in PRO versus ULTRA, regardless of gender. In conclusion, gender did not modify the treatment effect of PRO versus ULTRA on clinical outcomes, except for 30-day DS, which was decreased in men (vs women) who received ULTRA (vs PRO).


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Masculino , Femenino , Estenosis de la Válvula Aórtica/cirugía , Factores Sexuales , Anciano de 80 o más Años , Anciano , Resultado del Tratamiento , Complicaciones Posoperatorias/epidemiología , Válvula Aórtica/cirugía
6.
J Cardiovasc Dev Dis ; 11(1)2024 Jan 22.
Artículo en Inglés | MEDLINE | ID: mdl-38276659

RESUMEN

BACKGROUND: Current European guidelines support transcatheter aortic valve implantation (TAVI) in intermediate-to-low-risk patients ≥75 years-old, but its prognostic relevance is unknown. METHODS: Intermediate-to-low-risk (The Society of Thoracic Surgeons score <8%) patients enrolled in the HORSE registry were included. We compared the populations aged under 75 with those over 75. The primary endpoint was all-cause mortality. RESULTS: A total of 2685 patients were included: 280 (8.6%) < 75 and 2405 ≥ 75 years. Through a mean follow-up of 437 ± 381 days, 198 (8.2%) and 23 (8.2%) patients died in the two arms without statistically significant differences (log-rank p = 0.925). At Cox regression analysis, age did not predict the occurrence of all-cause death, neither as a continuous variable (HR 1.01, 95% CI 0.99-1.04, p = 0.294) nor dichotomizing according to the prespecified cutoff of 75 years (HR 0.97, 95% CI 0.63-1.51, p = 0.924). Time-to-event ROC curves showed low accuracy of age to predict all-cause mortality (area under the curve of 0.54 for both 1-year and 2-year outcomes). CONCLUSIONS: TAVI has comparable benefits across age strata for intermediate-to-low-risk patients. The age cutoff suggested by the current guidelines is not predictive of the risk of adverse events during hospital stays or of all-cause mortality through a mid-term follow-up.

7.
EuroIntervention ; 20(1): 95-103, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-37982161

RESUMEN

BACKGROUND: Midterm comparative analyses of the latest iterations of the most used Evolut and SAPIEN platforms for transcatheter aortic valve implantation (TAVI) are lacking. AIMS: We aimed to compare 1-year clinical outcomes of TAVI patients receiving Evolut PRO/PRO+ (PRO) or SAPIEN 3 Ultra (ULTRA) devices in current real-world practice. METHODS: Among patients enrolled in the OPERA-TAVI registry, patients with complete 1-year follow-up were considered for the purpose of this analysis. One-to-one propensity score matching was used to compare TAVI patients receiving PRO or ULTRA devices. The primary endpoint was a composite of 1-year all-cause death, disabling stroke and rehospitalisation for heart failure. Five prespecified subgroups of patients were considered according to leaflet and left ventricular outflow tract calcifications, annulus dimensions and angulation, and leaflet morphology. RESULTS: Among a total of 1,897 patients, 587 matched pairs of patients with similar clinical and anatomical characteristics were compared. The primary composite endpoint did not differ between patients receiving PRO or ULTRA devices (Kaplan-Meier [KM] estimates 14.0% vs 11.9%; log-rank p=0.27). Patients receiving PRO devices had higher rates of 1-year disabling stroke (KM estimates 2.6% vs 0.4%; log-rank p=0.001), predominantly occurring within 30 days after TAVI (1.4% vs 0.0%; p=0.004). Outcomes were consistent across all the prespecified subsets of anatomical scenarios (all pinteraction>0.10). CONCLUSIONS: One-year clinical outcomes of patients undergoing transfemoral TAVI and receiving PRO or ULTRA devices in the current clinical practice were similar, but PRO patients had higher rates of disabling stroke. Outcomes did not differ across the different anatomical subsets of the aortic root.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Accidente Cerebrovascular , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Sistema de Registros , Accidente Cerebrovascular/etiología , Diseño de Prótesis
10.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-38152923

RESUMEN

OBJECTIVES: Relevant paravalvular leakage (PVL) due to prosthesis dislodgement is a rare but potentially severe complication after transcatheter mitral valve implantation (TMVI). Due to the epicardial anchoring mechanism of the Tendyne® TMVI system, repositioning of the valve stent may be possible by retensioning of the tether. This multicentre study aimed to investigate the procedural and short-term safety as well as efficacy of retensioning manoeuvres. METHODS: From 2017 to 2021, N = 18 patients who underwent secondary tether retensioning were identified. Baseline, procedural and follow-up data were available from N = 11 patients and analysed according to the Mitral Valve Research Consortium definitions. Continuous variables are shown as median with interquartile range. RESULTS: All patients [age 75 years (73.5, 85.0), 64% male (N = 7), EuroSCORE II 6.2% (5.8, 11.6)] presented with post-procedural PVL [63.6% (N = 7) with PVL ≥3+]. Of these, 54% (N = 6) showed signs of haemolysis. The majority were severely symptomatic [New York Heart Association ≥III (91%, N = 10)]. Procedural outcomes revealed no acute complications and no mortality. At discharge, PVL was completely eliminated in 91% (N = 10) of patients with 1 case of remaining moderate PVL. At 30 days, Mitral Valve Research Consortium device success was achieved in 82% (N = 9) of patients. Two patients required open surgical mitral valve replacement due to persistent and recurrent PVL. In 89% (N = 8) of patients with successful retensioning procedure, New York Heart Association class was I/II. There was no 30-day mortality. CONCLUSIONS: This multicentre study demonstrates technical feasibility, procedural safety and acute efficacy of retensioning procedures in the majority of patients. The potential to retension the tether in transapical TMVI may provide additional management advantages in populations at high surgical risk.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Masculino , Anciano , Femenino , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Insuficiencia de la Válvula Mitral/cirugía , Resultado del Tratamiento , New York , Cateterismo Cardíaco/métodos
11.
JACC Case Rep ; 26: 102062, 2023 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-38094171

RESUMEN

We present the case of an 82-year-old man with a history of inferior vena cava filter implantation and concomitant severe mitral regurgitation requiring transcatheter edge-to-edge repair. Despite being deemed ineligible for transfemoral access as technically challenging, he successfully underwent mitral transcatheter edge-to-edge repair after crossing and dilatation of the inferior vena cava filter. (Level of Difficulty: Intermediate.).

12.
EuroIntervention ; 19(11): e926-e936, 2023 Dec 18.
Artículo en Inglés | MEDLINE | ID: mdl-37946539

RESUMEN

BACKGROUND: In the context of primary mitral regurgitation (PMR), the selection of patients for transcatheter edge-to-edge repair (TEER) does not include a systematic assessment of PMR-associated cardiac remodelling. AIMS: We aimed to investigate the epidemiology and prognostic significance of different phenotypes of extra-mitral valve (MV) cardiac involvement in a large series of patients with PMR referred for TEER. METHODS: The study included 654 patients from the multicentre Italian GIOTTO registry, stratified into groups according to extra-mitral valve (MV) cardiac involvement. The primary endpoint was all-cause death at 2-year follow-up. RESULTS: Patients with no cardiac involvement (NI; n=58), left heart involvement (LHI; n=343) and right heart involvement (RHI; n=253) were analysed. Acute technical success was achieved in 98% of patients. Kaplan-Meier curve analysis revealed significantly worse survival in patients with LHI and RHI (p=0.041). On multivariate Cox regression analysis, extra-MV cardiac involvement, haemoglobin level and technical success were independent predictors of the primary endpoint occurrence. CONCLUSIONS: Grading cardiac involvement may help refine risk stratification, since at least 1 group of extra-MV cardiac involvement represents in itself a negative predictor of midterm outcome.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estimación de Kaplan-Meier , Análisis Multivariante , Pacientes , Resultado del Tratamiento , Cateterismo Cardíaco
13.
Artículo en Inglés | MEDLINE | ID: mdl-37931791

RESUMEN

Percutaneous closure of a patent foramen ovale (PFO), a common variation of interatrial septum anatomy, is a commonly performed procedure in the catheterization laboratory to reduce the risk of recurrent stroke in selected patients and to treat other PFO-related syndromes. In the last twenty years, disc-based devices have represented the armamentarium of the interventional cardiologist; recently, suture-based devices have become an attractive alternative, despite limited data regarding their long-term performance. The present review gives an overview of the current evidence regarding suture-based PFO closure, the device's characteristics, the echocardiographic evaluation of the PFO anatomy, and recommendations for patient selection. A detailed procedural guide is then provided, and potential complications and future developments in the field are discussed.

14.
JACC Cardiovasc Interv ; 16(21): 2600-2610, 2023 11 13.
Artículo en Inglés | MEDLINE | ID: mdl-37877913

RESUMEN

BACKGROUND: The fourth-generation mitral transcatheter edge-to-edge repair (M-TEER) device introduced an improved clip deployment sequence, independent leaflet grasping, and 2 wider clip sizes to tailor the treatment of patients with mitral regurgitation (MR) for a broad range of anatomies. The 30-day safety and effectiveness of the fourth-generation M-TEER device were previously demonstrated. OBJECTIVES: The aim of this study was to evaluate 1-year outcomes in a contemporary, real-world cohort of subjects treated with the MitraClip G4 system. METHODS: EXPAND G4 is an ongoing prospective, multicenter, international, single-arm study that enrolled subjects with primary and secondary MR. One-year outcomes included MR severity (echocardiographic core laboratory assessed), heart failure hospitalization, all-cause mortality, functional capacity (NYHA functional class), and quality of life (Kansas City Cardiomyopathy Questionnaire). RESULTS: A total of 1,164 subjects underwent M-TEER from 2020 to 2022. At 1 year, there was a durable reduction in MR to mild or less in 92.6% and to none or trace in 44.2% (P < 0.0001 vs baseline). Few subjects had major adverse events through 1 year (<2% for myocardial infarction, surgical reintervention, or single-leaflet device attachment). The 1-year Kaplan-Meier estimates for all-cause mortality and heart failure hospitalization were 12.3% and 16.9%. Significant improvements in functional capacity (NYHA functional class I or II in 82%; P < 0.0001 vs baseline) and quality of life (18.5-point Kansas City Cardiomyopathy Questionnaire overall summary score improvement; P < 0.0001) were observed. CONCLUSIONS: M-TEER with the fourth-generation M-TEER device was safe and effective at 1 year, with durable reductions in MR severity to ≤1+ in more than 90% of patients and concomitant improvements in functional status and quality of life.


Asunto(s)
Cardiomiopatías , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Calidad de Vida , Estudios Prospectivos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía
15.
G Ital Cardiol (Rome) ; 24(10 Suppl 2): 42S-52S, 2023 10.
Artículo en Italiano | MEDLINE | ID: mdl-37767847

RESUMEN

BACKGROUND: Myocardial ischemia (INOCA) and acute myocardial infarction with non-obstructive coronary artery disease (MINOCA) represent emerging entities in the landscape of interventional cardiology. These conditions have heterogeneous pathophysiological mechanisms and clinical presentations, complex diagnostics, and high prognostic significance. METHODS: This survey was carried out jointly by the GISE Young Committee with the support of the SICI-GISE Society and the ICOT group with the aim of evaluating the implementation of diagnostic-therapeutic pathways in cases of suspected/confirmed INOCA and MINOCA diseases. A web-based questionnaire based on 22 questions was distributed to SICI-GISE and ICOT members. RESULTS: The survey was distributed to 1550 physicians with 104 (7%) responses. The majority of participants included interventional cardiologists (70%), in two-thirds of cases working in centers with high volume of procedures (>1000 coronary angiographies/year), who estimated a <10% annual rate of INOCA and MINOCA cases in their case load. Approximately 25% of the participants stated that they do not have the option of performing any investigation for the evaluation of patients with suspected INOCA, and less than 50% make use of advanced invasive testing for the diagnosis of MINOCA, including physiology and intravascular imaging tests. It also turns out that about 50% of respondents reported the present and future absence of dedicated diagnostic-therapeutic pathways. Even with a high perception of the clinical relevance of these diseases, about 40% of the respondents rely on clinical experience or do not deal with their management, also reporting a low prevalence of dedicated follow-up care (20% of cases followed at dedicated outpatient clinics). Factors predominantly limiting the prevalence of appropriate diagnostic and treatment pathways included the cost of materials, lack of training and expertise of practitioners, and of solid data on the long-term clinical efficacy of treatments. CONCLUSIONS: Currently, the proper management of INOCA and MINOCA disease is widely advocated but poorly implemented in clinical practice. To reverse the trend and solve the remaining controversies, it is necessary to enhance awareness, produce robust scientific data, and implement dedicated pathways for patients.


Asunto(s)
Enfermedad de la Arteria Coronaria , Infarto del Miocardio , Isquemia Miocárdica , Humanos , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/terapia , MINOCA , Laboratorios , Infarto del Miocardio/diagnóstico , Infarto del Miocardio/terapia , Isquemia Miocárdica/diagnóstico , Isquemia Miocárdica/terapia , Angiografía Coronaria/métodos , Cateterismo , Vasos Coronarios
16.
Catheter Cardiovasc Interv ; 102(5): 931-943, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37668097

RESUMEN

BACKGROUND: Evidence of clinical impact of PPM after TAVI is conflicting and might vary according to the type of valve implanted. AIMS: To assess the clinical impact of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI) with balloon-expandable (BEV) and self-expandable valves (SEV) in patients with small annuli. METHODS: TAVI-SMALL 2 enrolled 628 patients in an international retrospective registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 ) treated with transfemoral TAVI at 16 high-volume centers between 2011 and 2020. Analyses were performed comparing patients with less than moderate (n = 452), moderate (n = 138), and severe PPM (n = 38). Primary endpoint was incidence of all-cause mortality. Predictors of all-cause mortality and PPM were investigated. RESULTS: At a median follow-up of 380 days (interquartile range: 210-709 days), patients with severe PPM, but not moderate PPM, had an increased risk of all-cause mortality when compared with less than moderate PPM (log-rank p = 0.046). Severe PPM predicted all-cause mortality in patients with BEV (hazard ratio [HR]: 5.20, 95% confidence interval [CI]: 1.27-21.2) and intra-annular valves (IAVs, HR: 4.23, 95% CI: 1.28-14.02), and it did so with borderline significance in the overall population (HR: 2.89, 95% CI: 0.95-8.79). Supra-annular valve (SAV) implantation was the only predictor of severe PPM (odds ratio: 0.33, 95% CI: 0.13-0.83). CONCLUSIONS: Patients with small aortic annuli and severe PPM after TAVI have an increased risk of all-cause mortality at early term follow-up, especially after IAV or BEV implantation. TAVI with SAV protected from severe PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Estudios Retrospectivos , Diseño de Prótesis , Resultado del Tratamiento , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos
17.
JACC Cardiovasc Interv ; 16(16): 2004-2017, 2023 08 28.
Artículo en Inglés | MEDLINE | ID: mdl-37480891

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Incidencia , Bloqueo de Rama , Pronóstico , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
18.
JACC cardiovasc. interv ; (23): (23)00846-4, jul.2023. ilus
Artículo en Inglés | Sec. Est. Saúde SP, CONASS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1444382

RESUMEN

OBJECTIVES: The authors sought to evaluate the incidence, predictors, and outcomes of new permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement (TAVR) with contemporary self-expanding valves (SEV). BACKGROUND: Need for PPI is frequent post-TAVR, but conflicting data exist on new-generation SEV and on the prognostic impact of PPI. METHODS: This study included 3,211 patients enrolled in the multicenter NEOPRO (A Multicenter Comparison of Acurate NEO Versus Evolut PRO Transcatheter Heart Valves) and NEOPRO-2 (A Multicenter Comparison of ACURATE NEO2 Versus Evolut PRO/PRO+ Transcatheter Heart Valves 2) registries (January 2012 to December 2021) who underwent transfemoral TAVR with SEV. Implanted transcatheter heart valves (THV) were Acurate neo (n = 1,090), Acurate neo2 (n = 665), Evolut PRO (n = 1,312), and Evolut PRO+ (n = 144). Incidence and predictors of new PPI and 1-year outcomes were evaluated. RESULTS: New PPI was needed in 362 patients (11.3%) within 30 days after TAVR (8.8%, 7.7%, 15.2%, and 10.4%, respectively, after Acurate neo, Acurate neo2, Evolut PRO, and Evolut PRO+). Independent predictors of new PPI were Society of Thoracic Surgeons Predicted Risk of Mortality score, baseline right bundle branch block and depth of THV implantation, both in patients treated with Acurate neo/neo2 and in those treated with Evolut PRO/PRO+. Predischarge reduction in ejection fraction (EF) was more frequent in patients requiring PPI (P = 0.014). New PPI was associated with higher 1-year mortality (16.9% vs 10.8%; adjusted HR: 1.66; 95% CI: 1.13-2.43; P = 0.010), particularly in patients with baseline EF <40% (P for interaction = 0.049). CONCLUSIONS: New PPI was frequently needed after TAVR with SEV (11.3%) and was associated with higher 1-year mortality, particularly in patients with EF <40%. Baseline right bundle branch block and depth of THV implantation independently predicted the need of PPI.


Asunto(s)
Marcapaso Artificial
19.
Am J Cardiol ; 200: 178-187, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37331223

RESUMEN

Despite the growing experience with MitraClip in the broad spectrum of mitral regurgitation (MR), limited data are available regarding the independent prognostic role on survival of different mitral regurgitation etiology subtypes. We sought to evaluate the impact of flail leaflet etiology in a large series of patients with primary MR (PMR) who underwent MitraClip treatment. The study included 588 patients with significant PMR from the multicenter GIOTTO (Italian Society of Interventional Cardiology [GIse] registry Of Transcatheter treatment of mitral valve regurgitaTiOn), stratified into 2 groups according to MR etiology: flail+ (n = 300) and flail- (n = 288). The primary end point was a composite of cardiac death and first rehospitalization for heart failure (HF). To account for the baseline differences, patients were propensity score-matched 1:1. Flail leaflet etiology was present in about a half of the patients. Acute technical success was achieved in 98% of the overall cohort, with no significant differences between the study groups (p = 0.789). At the 2-year Kaplan-Meier analysis, the primary end point occurred in 13% of flail+ patients compared with 23% in flail- (p = 0.009). The flail+ group presented lower rates of both cardiac death and rehospitalization for HF, whereas a similar overall death rate was observed between the groups. A multivariate Cox regression analysis identified flail leaflet etiology as an independent predictor of favorable outcome in terms of the primary end point (hazard ratio 0.141, 95% confidence interval 0.049 to 0.401, p <0.001). After propensity score matching, flail+ patients had confirmed lower rates of cardiac mortality and rehospitalization for HF but similar rates of overall death. In conclusion, flail leaflet-related etiology was common in patients with PMR who underwent MitraClip treatment and was an independent predictor of midterm favorable clinical outcomes.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Pronóstico , Resultado del Tratamiento , Modelos de Riesgos Proporcionales , Insuficiencia Cardíaca/complicaciones , Muerte , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
20.
JACC Cardiovasc Interv ; 16(11): 1332-1343, 2023 06 12.
Artículo en Inglés | MEDLINE | ID: mdl-37316145

RESUMEN

BACKGROUND: The benefit related to the use of preprocedural computed tomography angiography (CCTA) on top of periprocedural echocardiography to plan percutaneous left atrial appendage closure (LAAC) procedures is still unclear. OBJECTIVES: The authors sought to evaluate the impact of preprocedural CCTA on LAAC procedural success. METHODS: In the investigator-initiated SWISS-APERO (Comparison of Amplatzer Amulet and Watchman Device in Patients Undergoing Left Atrial Appendage Closure) trial, patients undergoing echocardiography-guided LAAC were randomly assigned to receive the Amulet (Abbott) or Watchman 2.5/FLX (Boston Scientific) device across 8 European centers. According to the study protocol ongoing at the time of the procedure, the first operators had (CCTA unblinded group) or did not have (CCTA blinded group) access to preprocedural CCTA images. In this post hoc analysis, we compared blinded vs unblinded procedures in terms of procedural success defined as complete left atrial appendage occlusion as evaluated at the end of LAAC (short-term) or at the 45-day follow-up (long-term) without procedural-related complications. RESULTS: Among 219 LAACs preceded by CCTA, 92 (42.1%) and 127 (57.9%) were assigned to the CCTA unblinded and blinded group, respectively. After adjusting for confounders, operator unblinding to preprocedural CCTA remained associated with a higher rate of short-term procedural success (93.5% vs 81.1%; P = 0.009; adjusted OR: 2.76; 95% CI: 1.05-7.29; P = 0.040) and long-term procedural success (83.7% vs 72.4%; P = 0.050; adjusted OR: 2.12; 95% CI: 1.03-4.35; P = 0.041). CONCLUSIONS: In a prospective multicenter cohort of clinically indicated echocardiography-guided LAACs, unblinding of the first operators to preprocedural CCTA images was independently associated with a higher rate of both short- and long-term procedural success. Further studies are needed to better evaluate the impact of preprocedural CCTA on clinical outcomes.


Asunto(s)
Apéndice Atrial , Humanos , Apéndice Atrial/diagnóstico por imagen , Estudios Prospectivos , Resultado del Tratamiento , Tomografía Computarizada por Rayos X , Angiografía por Tomografía Computarizada
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...